Urology Laser

Urology Laser 30W-300W/45W–450W/70W-700W
1940nm Wave

Urology Laser 30W–300W / 45W–450W / 70W–700W (1940 nm) is a thulium fiber laser system designed for advanced urological procedures, delivering precise energy absorption for efficient stone management and soft-tissue applications.

Dental Laser Device

Thulium Fiber Laser Technology

Thulium Fiber Laser (TFL) technology operates at a 1940 nm wavelength, offering high absorption in water-rich tissues. This characteristic enables highly precise and controlled laser energy delivery during urological procedures. The system supports efficient stone fragmentation with controlled pulse modulation. Reduced retropulsion enhances procedural stability and visibility. Adjustable power settings allow customization based on clinical requirements. Overall, TFL technology improves precision and energy efficiency in modern urology.

Fine Fiber Compatibility

The system supports the use of fine-diameter laser fibers for enhanced maneuverability. Smaller fibers improve scope deflection within flexible ureteroscopes. This allows better access to challenging anatomical locations. Fine fiber use also contributes to improved irrigation flow during procedures. Enhanced flexibility supports precise targeting of stones. The design optimizes performance in minimally invasive endourological techniques. It also supports efficient stone dusting strategies with improved overall procedural precision and control efficiency.

User-Centric Surgical Design

The laser system is designed with an intuitive interface for simplified operation. Adjustable parameters can be configured quickly during procedures. Real-time monitoring supports controlled and stable energy delivery. Its compact structure allows seamless integration into operating environments. Ergonomic and workflow-focused engineering design considerations significantly improve workflow efficiency in modern surgical settings. The design supports reliable, safe, consistent, durable, and efficient long-term clinical performance standards.

Key Features of Vikrant Thulium Fiber Urology Laser

  • Advanced 1940 nm Thulium Fiber Technology
    The system operates at a 1940 nm wavelength, offering excellent absorption in water-rich tissues. This ensures precise cutting, efficient vaporization, and minimal thermal spread for safer procedures.
  • High Power with Superior Performance
    Equipped with high peak power output, the laser enables faster stone fragmentation and efficient soft tissue management, improving overall surgical productivity.
  • Minimal Retropulsion for Precision Treatment
    The laser minimizes stone movement during lithotripsy, allowing better control and accuracy, which reduces operative time and enhances outcomes.
  • Dusting & Fragmentation Capability
    It supports both fine dusting and fragmentation techniques, enabling surgeons to tailor treatment based on stone size and composition.
  • Multiple Operating Modes
    With Super Pulsed, Pulsed, Continuous Wave (CW), and Burst modes, the system offers flexibility to perform a wide range of urological procedures effectively.
  • Wide Fiber Compatibility
    Compatible with fibers ranging from 150 µm to 600 µm, the device supports diverse clinical applications including RIRS, PCNL, and prostate treatments.
  • Enhanced Hemostasis
    Provides excellent coagulation and hemostasis, minimizing intraoperative bleeding and ensuring a clear surgical field.
  • Compact Air-Cooled Design
    The air-cooled system eliminates the need for external cooling units, making it low-maintenance, space-saving, and easy to install.
  • User-Friendly Interface with Preset Protocols
    Features an intuitive touchscreen interface with pre-set treatment parameters, enabling quick setup and ease of use for surgeons.
  • Low Noise & Energy Efficient Operation
    Designed for quiet performance and optimized energy consumption, ensuring a comfortable operating environment and reduced operational costs.
  • Consistent Energy Delivery
    Delivers stable and uniform energy output, ensuring predictable results and enhanced procedural safety.
  • Minimally Invasive Approach
    Supports minimally invasive techniques, leading to reduced patient discomfort, shorter hospital stays, and faster recovery.
  • Versatility Across Urology Procedures
    Ideal for a wide range of applications including kidney stones, ureteral stones, bladder stones, and BPH treatments.
  • Reduced Carbonization Effect
    Minimizes tissue charring and carbonization, improving visibility and promoting faster healing.
  • High Frequency & Low Pulse Energy Advantage
    Operates at high frequency with low pulse energy, enabling fine dusting of stones and reducing complications.
  • Durable & Reliable Performance
    Built with robust engineering for long-term clinical use, ensuring consistent performance across high patient volumes.
  • Cost-Effective Solution
    Offers lower maintenance costs and compatibility with reusable fibers, making it an economical choice for healthcare facilities.

    Clinical Advantages

    The Vikrant Thulium Fiber Urology Laser offers enhanced surgical precision with minimal tissue damage, ensuring safer procedures and improved outcomes. Its advanced energy delivery system supports faster treatment, reduced operative time, and greater patient comfort, making it a reliable choice for modern urology practices.

Why Urology TFL Laser?

Superior Stone Fragmentation

High water absorption at 1940 nm enables efficient stone dusting and fragmentation with reduced retropulsion during lithotripsy.

Precise Energy Modulation

Adjustable pulse energy and frequency allow customized treatment parameters for different stone types and clinical scenarios.

Fine Fiber Advantage

Compatibility with smaller laser fibers improves scope deflection and access to challenging anatomical locations.

Dentist using laser

Minimally Invasive Efficiency

Controlled thermal interaction supports effective treatment while promoting procedural stability and faster patient recovery.

Clinical Specialities and Advantages

Kidney Stone Management

Precise fragmentation for quick and effective stone removal.

BPH Treatment

Minimally invasive solution for enlarged prostate with recovery.

Ureteral Stricture

Accurate treatment to restore smooth urine flow.

Bladder Tumor Ablation

Safe removal of abnormal tissues with precision.

Soft Tissue Surgery

Controlled cutting and coagulation for better outcomes.

Endourology Procedures

Advanced techniques for painless, quick recovery treatments.

High Precision

Provides accurate treatment with minimal thermal damage.

Faster Procedures

Enables quick stone fragmentation and reduced operation time.

Low Retropulsion

Keeps stones stable for better control during treatment.

Better Hemostasis

Minimizes bleeding and ensures clear surgical visibility.

Quick Recovery

Supports minimally invasive procedures with faster healing.

Cost-Effective

Offers reliable performance with low maintenance needs.

Carry Case
Thulium Fiber Laser
Dental Kit
Fine Fiber
Carry Case
Advanced Stone Management

Risk & Safety Compliance

  • Foot Switch Control
    Enables hands-free operation, allowing surgeons to activate the laser with precision and ease.
  • Emergency Switch
    Provides immediate system shutdown in case of emergencies, ensuring maximum safety.
  • Emission Time Control
    Controls the duration of laser emission to prevent overexposure and enhance procedural safety.
  • ON/Off Switch
    Ensures quick and safe power control for smooth operation.
  • OD+3 Protective Eyewear Support
    Offers protection against laser exposure, safeguarding doctors’ eyes during procedures.
  • Password Protection
    Restricts unauthorized access, allowing only trained professionals to operate the system.

Safety Assurance

Built with multiple layers of protection, the system ensures reliable and secure performance in every procedure. Its integrated safety features help minimize risks, enhance operator confidence, and maintain a safe clinical environment.

Included Accessories

Carry Case
Doctor's Goggle
Dental Kit
Bare fiber – 400 Micron
Carry Case
Wireless & Wired foot switch
Dental Kit
Metallic Carry Case

Fill the form below and our specialist will contact you.