Vital Lase (15 W/980nm-HD)

Vital Laser 15W
980 nm HD

The Proctology Laser 15W – 980 nm HD from Intense Medical & Dental System Pvt Ltd (IMDSL) is designed for minimally invasive anorectal procedures using a 980 nm wavelength for precise soft-tissue coagulation.

Dental Laser Device

Operational Safety Controls

Footswitch-enabled activation for precise and controlled laser use Emergency stop function for immediate shutdown during Dedicated ON/OFF switch for safe and quick device handling

Exposure & Usage Management

Controlled emission time to prevent overexposure Adjustable modes for customized and safe treatment delivery Consistent energy output for predictable clinical performance

User Protection & Security

Password protection to restrict unauthorized access OD+3 and above eye protection for doctor and staff safety Designed to meet clinical safety standards and protocols

Key Advancements & Benefits

  • Minimally Invasive Approach
    Ensures reduced tissue damage, minimal bleeding, and faster patient recovery.
  • High Precision Laser Technology
    The 980nm wavelength delivers accurate cutting and effective coagulation for better surgical control.
  • Reduced Post-Operative Pain
    Patients experience less discomfort, leading to quicker return to daily activities.
  • Enhanced Healing & Cosmetic Outcomes
    Promotes better healing with minimal scarring and improved overall results.
  • Versatile Applications
    Suitable for treating conditions like piles, fissures, fistula, and other anorectal disorders.
  • Preloaded Treatment Protocols
    Simplifies procedures with ready-to-use settings for consistent and reliable outcomes.
  • Smart Cooling System
    Supports long-duration procedures while maintaining optimal device performance.
  • User-Friendly Operation
    Ergonomic design with footswitch control ensures ease of use and hands-free operation.

Why It Matters for Your Practice

With the growing demand for advanced and minimally invasive treatments, Vital Lase-HD empowers clinics and hospitals to deliver superior care while improving operational efficiency. It not only enhances clinical outcomes but also helps in building patient trust, increasing case acceptance, and driving long-term practice growth.

Why Vital Laser?

Proudly Indian, CDSCO Approved

Manufactured by a trusted Indian company and registered with CDSCO, ensuring reliability, safety, and compliance with national standards.

Single Wavelength Efficiency

A focused 980nm wavelength delivers consistent performance across procedures, simplifying operation while maintaining clinical excellence.

Smart Cooling System

Maintains optimal device temperature, enhancing longevity and ensuring uninterrupted performance during extended procedures.

Dentist using laser

Hands-Free Ergonomic Control

Equipped with an advanced footswitch system, enabling seamless, hands-free operation for improved procedural efficiency, enhanced precision, and greater surgeon comfort during extended procedures.

Clinical Specialities and Advantages

Anorectal Disorders

Covers overall conditions of the anus and rectum

Hemorrhoidal (Piles) Treatment

Laser hemorrhoidoplasty, advanced piles management

Fistula Management

Laser-assisted fistula closure – FiLaC procedures

Fissure Treatment

Chronic anal fissure with laser sphincterotomy support

Pilonidal Sinus Treatment

Laser ablation for sinus tract healing

Anal & Rectal Lesions / Polyps

Removal of warts, polyps, and benign growths

Faster Recovery

Supports quicker healing, allowing patients to return to daily life sooner.

Less Pain & Discomfort

Minimally invasive approach results in reduced post-operative pain.

Reduced Bleeding

Strong coagulation minimizes blood loss during procedures.

Lower Risk of Complications

Reduces chances of infection and recurrence.

Day-Care Procedures

Allows most treatments to be performed without hospitalization.

Improved Clinical Efficiency

Speeds up procedures and enhances overall workflow.

Carry Case
Vital Laser-HD
Dental Kit
Anal Fissure
Carry Case
15W / 980 nm

Risk & Safety Compliance

Vital Lase-HD is engineered with a strong focus on safety, ensuring complete risk control and compliance with modern clinical standards. Every feature is designed to protect both the practitioner and the patient while maintaining precise and efficient treatment delivery.

Comprehensive Safety Features

  • Foot Switch Control
    Enables controlled laser activation, reducing accidental exposure and ensuring precise energy delivery.
  • Emergency Stop Function
    Instantly halts operation in critical situations, enhancing procedural safety and quick response.
  • Controlled Emission Time
    Allows accurate management of laser exposure duration, minimizing the risk of over-treatment.
  • Dedicated ON/OFF Switch
    Ensures safe device handling with clear operational control and quick accessibility.
  • Password Protection System
    Prevents unauthorized usage, maintaining security and compliance within clinical environments.
  • Advanced Eye Protection (OD+3 and Above)
    Designed to safeguard doctors and staff from laser exposure, ensuring adherence to laser safety standards.

Included Accessories

Carry Case
Doctor Goggle
Dental Kit
Interlock key
Carry Case
Wired & Wireless foot switch
Dental Kit
Metallic Carry Case

Fill the form below and our specialist will contact you.